RJ-6000 Series USER GUIDE Functions Edition
Accracy Adjustment Plot
How to Set Parameters
Step 3
Look at pattern A on your print. Use
the [VALUE +] and [VALUE -] keys to
enter the number of a line with no off-
set.
Step 4
Press [ENTER] key to confirm the
value specified for pattern A.
Step 5
Look at pattern B on your print. Use
the [VALUE +] and [VALUE -] keys to
enter the number of a line with no off-
set.
Step 6
Press [ENTER] key to confirm the
value specified for pattern B.
Step 7
Look at pattern C on your print. Use
the [VALUE +] and [VALUE -] keys to
enter the number of a line with no off-
set.
Step 8
Press [ENTER] key to confirm the
value specified for pattern C.
Step 9
Permanent display is restored.
Pa t ternA: 4
Pa t ternA: 6
Pa t ternB: 4
Pa t ternB: 5
Pa t ternC: 4
Pa t ternC: 4
Plot OK