Rockhopper II series printers – Maintenance Manual
131
AP-74065, Rev. 1.2, 27/09/04
4.11.4. Replacing the waste bottle box sensor assembly (RH II 4H)
Step 1 : Follow the instructions in "Replacing the waste fluid bottle assembly" to remove the waste fluid
bottle assembly.
Caution :
Waste ink will remain inside the tubes. Be careful that the ink is not spilled from the tube
onto the printer or items close to the printer.
Step 2 : Remove the waste liquid BOX sensor assembly connector from the rear side cap R.
1 = Rear side cap R 2 = Waste liquid BOX sensor assembly connector
Step 3 : Remove the waste liquid box assy from the stand.