Rockhopper II series printers – Maintenance Manual
187
AP-74065, Rev. 1.2, 27/09/04
5.9.2. PF Motor Endurance Menu
This menu performs endurance running for the PF motor.
You can drive the PF motor according to your desired settings. The available settings are shown below.
Setup item Description Parameters Remarks
Media feed amount Sets amount of media
feeds per endurance
operation.
0 to 100 Unit: mm
Number of endurance
running cycles
Set the number of
endurance running
cycles
-1 to 10000
Notes :
¾ The motor drive parameters are determined as follows depending on the media feed
amount.
Speed 54 cps
Acceleration 0.1 G
Deceleration 0.1 G
¾ If the number of endurance running cycles is set to -1, the units continuously repeat
endurance running until a key input is given from the operation panel.
¾ The maximum counter value for endurance running cycles is 99999999 (up to 8-digit
number). If the number of cycles exceeds the maximum value, the counter is reset
to 0.
* FeedAmount *
0 – 100.0 mm + Media feed amount
0.1 mm -
ENTER
* LifeCount *
Count
-1 10000 +
Number of endurance running cycles
50 -
ENTER
* PFmotor *
Count 5 Perform endurance running
ENTER
* PFmotor *
End 50